This can be a lot of work.
Can radon be vented through a wall.
Ideally for a roof vented system the fan should be mounted in the attic space.
Because the radon vac side wall system evacuates through the basement side wall homeowners can avoid having pvc pipe run vertically through living areas or outside of their homes to the.
The vent pipe discharge point is under the overhang and approximately 3 feet from the window.
One of the newest fans designed specifically for radon mitigation vents directly through the side wall similar to a dryer vent using an aspiration hood to mix and disperse the radon gas.
Subtle side wall venting keeps the system out of sight by eliminating unsightly pvc pipe running on the homes exterior.
Using a sewer vent for your radon vent could be explosive and smelly.
If the fan was not operating sewer gasses could fall down the radon vent and settle under the house.
Called radon vact tm the proprietary system consists of a plug in fan exterior hood and installer purchased pvc pipe.
Keeping the vent pipe indoors keeps it warmer enhancing the stack effect.
Efficient motor operates quietly.
Because this system is power vented by a continuously running fan it can be vented through a suitable location on the roof or at a location along the exterior wall system provided the exit port is 10 feet away from any window or door and 2 feet above.
Ideally a radon vent especially a passive radon vent should penetrate the roof not a wall or rim joist.
Running the wires for a fan might mean fishing wire through a wall.
This is a serious plumbing code violation and safety issue.
The foundation wall is concrete block effectively providing a chimney all around the addition for radon to rise into the space.
Undoubtedly the radon problem was aggravated by the need to dig a very deep foundation wall 14 feet below grade at one corner in order to reach solid soil below fill material.
One of our competitor s incorrectly constructed systems.
Epa s radon mitigation standards require vent discharge points to be above the roofline and no less than 10 feet sideways or 2 feet above any windows or vents.
Saves this radon vac radon fan saves hundreds of dollars in extra materials and labor over a typical radon mitigation systems.
If you don t do it and the house tests high for radon it becomes much more difficult and expensive.
It means opening up walls and messing up painted drywall.
Because the radon vact tm side wall system evacuates through the basement side wall homeowners can avoid having pvc pipe run vertically through living areas or outside of their homes to the roof line.
If a roof penetration is impossible you can route the radon vent through the wall or rim joist and continue the riser up the outside of the building.